Install Your Flexplate
You must read and follow these instructions closely.
Applies to Reactor billet aluminum SFI 29.1 flexplates. Installation should be done by a qualified installer. Support the vehicle on rated jack stands, chock the wheels and disconnect the battery.
Download the Installation & Safety Sheet (PDF)
Before you start: balance check
Internal or external balance must match your crankshaft and rotating assembly. Reactor's stocked plates are internal balance only; verify your engine is internally balanced before installation. External-balance flexplates are special order; call 310-323-0065. If your combination needs external balance weight, confirm its orientation before torqueing.
Installation steps
- Check the part matches your application. Confirm engine family, crank flange bolt pattern, converter bolt circle, ring gear tooth count and balance type against the product listing before you start, or call 310-323-0065 to confirm. Your starter must match the ring gear tooth count.
- Clean and test-fit on the crank. Degrease the crank flange and flexplate mating face and dry them. Test-fit on the crank: the plate should seat fully and flush with no interference at dowels or reliefs. The Reactor aluminum flexplate may fit snugly over the crankshaft because of tight tolerances.
- Seat the flexplate evenly. Using a rubber mallet or a block of wood, tap the flexplate evenly so it sits flush against the crankshaft flange. Do not draw the flexplate up against the crankshaft with the bolts or an impact wrench.
- Threadlocker and torque the flexplate bolts. Use new fasteners of the correct grade, length and pitch for your crank, with at least 1x bolt diameter of thread engagement, flat washers only. Apply threadlocker, hand-start all bolts, snug in a star/alternating pattern, then torque in stages. Final torque per the bolt manufacturer's spec, not to exceed 75 lb/ft with threadlocker.
- Fit the converter to the flexplate. With the transmission fully seated, pull the converter forward to the flexplate. Set converter pull-out to your converter or transmission builder's spec (commonly about 0.060–0.125 in); shim or space per their guidance. Confirm the converter bolt circle matches the one on your flexplate listing, or call 310-323-0065 to confirm, and that the pilot engages the crank register without binding. Torque converter bolts to the OEM or converter spec.
- Check clearance and starter engagement. Rotate the engine by hand two full revolutions with no contact or noise, re-check converter pull-out after all bolts are torqued, look for witness marks around the bellhousing and block plate, and verify the starter pinion meshes with the ring gear with no tooth clash.
- Fill out the installation sheet. Read and fill out the flexplate installation sheet and keep it for your records.
After the first run
On first start, listen for abnormal noises and shut down to re-inspect if you hear any. After the first heat cycle or pass, check for leaks and contact.
Warning: Failure to follow these instructions completely could result in damage to the flexplate and may negatively impact future re-certification efforts.
SFI 29.1 re-certification
Reactor flexplates are built to SFI 29.1 with a replaceable steel starter ring gear, so they can be inspected and re-certified. Contact us first, then ship once approved. See SFI Re-Certification.
Need help?
Call 310-323-0065 for fitment help, or find a Reactor dealer.
Log your SFI serial number and we'll remind you every 2 years when it's due for re-certification.